Product Series Specifications
Specifications
Brand
Maximum Flow Rate
- Continuous Rating with Standard Trim: 420 USGPM (1600 L/min)
- Intermittent Rating with Standard Trim: 500 USGPM (1900 L/min)
- Continuous/Intermittent Rating with all Iron or LPG Trim: 315 USGPM (1200 L/min)
Repeatability
- ± 0.02 %
Viscosity
- Standard: 400 mPa.s (2,000 Seconds Saybolt Universal (SSU)) maximum
- Optional: 2 pascal seconds (Pa.s) (10,000 SSU) maximum and specify “High Viscosity Meter Clearances”
- Over 2 Pa.s: Specify ”High Viscosity Meter Clearances” and derate maximum flow rate in direct proportion to viscosity over 2 Pa.s. For example, at 4 Pa.s, derate maximum flow rate to 50 % of normal continuous rating 210 USGPM
Temperature - Standard Meter Clearances with
- Buna-N/PTFE: -20° F to 150° F (-29° C to 65° C)
- FKM: 10° F to 150° F (-12° C to 65° C)
- Low Temperature FKM: -50° F to 150° F (-46° C to 65° C)
Temperature - High Temperature Meter Clearances with
- Buna-N/PTFE: -20° F to 200° F (-29° C to 93° C)
- FKM: 10° F to 200° F (-12° C to 93° C)
- Low Temperature FKM: -50° F to 200° F (-46° C to 93° C)
Temperature - All Iron Trim with
- Buna-N: -20° F to 225° F (-29° C to 108° C)
- PTFE: -20° F to 400° F (-29° C to 205° C)
- FKM: 10° F to 400° F (-12° C to 205° C)
- Low Temperature FKM: -50° F to 400° F (-46° C to 205° C)