Images are representations only.
MACF Board (Standard) - Item 4
Price
Request a Quote
Stock
In Stock
Product Series Specifications
Specifications
Brand
AC Instrument Input Power
- Dual Voltage Input: 115 or 230 volts Alternating Current Power (VAC) via Switch Selection, 50/60 Hertz (Hz)
- Power Consumption: Approximately 9 W
- Power Interruption Tolerance: Interruption of Power greater than 0.05 seconds (typical) will cause an orderly Shutdown of the microFlow.net and the control valve will be immediately signaled to close
Digital (Meter Signal) Pulse Inputs
- Type: Optically-Isolated, Solid-State Voltage Sensors
- Quantity: Two
- Input Voltage Range: 5 to 28 Volts Direct Current (VDC) Compatible
- Pickup Voltage: 5 Vdc minimum
- Drop-Out Voltage: 1 Vdc maximum
- Current at Max. Voltage: 20 mA maximum
- Minimum Pulse Input Frequency: 3 Hz
- Input Level Duration: 83 microseconds (μS) minimum
Digital Control Inputs
- Type: Optically-Isolated, Solid-State Voltage Sensors
- Quantity: Three
- Input Voltage Range: 5 to 28 Vdc Compatible
- Pickup Voltage: 5 Vdc minimum
- Drop-Out Voltage: 1 Vdc maximum
- Current at Max. Voltage: 20 mA maximum
- Input Level Duration: 120 milliseconds (mS) minimum
Analog Inputs
- Type: 20-bit Analog-to-Digital Converters
- Function: One Resistance Temperature Device (RTD), One 4-20 mA
Temperature Resistance Temperature Detector (RTD)
- Type: Four-wire, 100-ohms Platinum RTD with a Temperature Coefficient at 32° F to be 0.00214 ohms per ohms°F (0.00385 ohms per ohms/°C)
- Temperature Range: -148° F to +572° F (-100° C to +300° C)
- Temperature Measurement Accuracy: ± 0.72° F (± 0.4° C) over the Specified Range
Current (4-20 mA) Input
- Type: Two-wire, 4-20 mA Current Loop Receiver, Programmable as to Function
- Span Adjustment: Program Adjustable
- Input Burden: 50 ohms
- Accuracy: ± 0.025 % of Range
- Resolution: One part in 1,048,576
- Voltage Drop: Two Volts maximum
- Sampling Rate: One Sample per 300 millesecond (ms) minimum
DC Power
- 12 Vdc ± 5 %, 180 mA maximum, Short-Circuit Protected
AC Digital Outputs
- Type: Optically Isolated, Solid-State Output, User-Programmable as to Function
- Quantity: Four
- Load Voltage Range: 90 to 280 Vac Root Mean Square (RMS) 48 to 63 Hz
- Steady-State Load Current Range: 0.05 amp (RMS) minimum to 0.50 amp (RMS) maximum into an Inductive Load
- Leakage Current at maximum Voltage Rating: 2.5 mA maximum at 240 Vac
- On-State Voltage Drop: 2.0 Vac at maximum Load
DC Digital Outputs
- Type: Optically Isolated, Solid-State Open-Collector Output, User-Programmable as to Function
- Quantity: Two
- Switch Blocking Voltage: 30 Vdc maximum
- Load Current: 150 mA maximum with 0.6 volt drop; Power Down - Normally Open
Pulse Output
- Type: Optically Isolated, Solid-State Open-Collector Output; Pulse-Output Units are Program-Selectable through the microLoad.net keypad or communications
- Switch-Blocking Voltage (Switch Off): 30 Vdc maximum
- Load Current (Switch On): 10 mA with 0.6 Volts drop
- Frequency Range: 0 to 3,000 Hz
- Duty Cycle: 50/50 (On/Off)
Environmental
- Ambient Operating Temperature: -13° F to 140° F (-25° C to +60° C)
- Humidity: 5 to 95 % with Condensation
- Enclosure: Explosion-proof (NEMA7, Class I, Groups C and D) and Watertight (NEMA 4X), IP65
Product Series Documentation
Documentation
Similar SKUs

554440101
microLoad.net™ Preset - Spare Parts
TechnipFMC
$778.00USD
Out of Stock
MACF Board with Transformer Assembly (Standard) - Item 6

554440102
microLoad.net™ Preset - Spare Parts
TechnipFMC
$1,824.00USD
Out of Stock
MACF Board with Transformer Assembly (OIML Battery Backup) - Item 6

236135102
microLoad.net™ Preset - Spare Parts
TechnipFMC
Request a Quote
Out of Stock
MACF Board (OIML Battery Backup) - Item 4

P8000010099
Smith Meter® AccuLoad® IV - Spare Parts for Model QT
TechnipFMC
$3,558.00USD
Out of Stock
A4B Replacement Board - Item 10

641746-401
Smith Meter® 4" Steel Model F4 - Spare Parts
TechnipFMC
$17.00USD
Out of Stock
Cap: Standard - Item 4

236133150001
microLoad.net™ Preset - Spare Parts
TechnipFMC
Request a Quote
Out of Stock
microLoad Board (MNET) - Item 2

P8000010107
Smith Meter® AccuLoad® IV - Spare Parts for Model QT
TechnipFMC
$2,648.00USD
Out of Stock
A4I Replacement Board - Item 12

P8000010099
Smith Meter® AccuLoad® IV - Spare Parts for Model SA-FCM
TechnipFMC
$3,558.00USD
Out of Stock
A4B Replacement Board - Item 7