Images are representations only.

Flexible I/O-PROFIBUS DP + Sub-modules - Item D

Price
Request a Quote
Stock
In Stock
Description
  • Only for Harsh Environment Transmitter Housing
  • Only for Harsh Environment Transmitter Housing

Specifications

Brand

Base Volumetric and Mass Flow Accuracy

  • Liquid: ± 0.15 % or ± 0.10 %
  • Gas: ± 0.75 % or Mass

Base Repeatability

  • Mass and Volume Flow Liquid: ± 0.075 %
  • Mass and Volume Flow Liquid (Option): ± 0.05 %
  • Mass Flow Gas: ± 0.35 %
  • Density Measurement (Liquid): ± 0.00025 g/cc

Base Temperature Accuracy

  • ± 0.9° F ± 0.003 (T-32) °F, (± 0.5° C ± 0.005 T °C)

Flow Ranges

  • Size: 1/2” - 3”
  • 0 - 6615 lb/min

Temperature Range

  • Ambient: -40° F to 140° F (-40° C to 60° C)
  • Standard Measurement Tube: 284° F to 302° F (140° C to 150° C)

Density Accuracy

  • Under Reference Conditions: ± 0.0005 g/cm²

Zero Point Stability

  • Size: 1/2” - 3” (0.024 - 0.66115 lb/min)

Nominal Pressure Rating

  • Pressure Class: 150 - 600
  • 275 - 1440 psig
  • Also available to DIN PN 16 to 100 and JIS 10K, 20K, 40K, 63K
  • Per ASME B16.5 Class 150, Class 300, Class 600 (-20° F to 100° F)
  • Sensor Body (Secondary Containment): Reference value pressure loading capacity 16 bar (232 psi)(Housing does not have pressure vessel classification)

Material of Construction

  • Sensor Housing: Stainless Steel, 1.4301 (304)
  • Measuring Tubes: Stainless Steel, 1.4539 (904L); Manifold: Stainless Steel, 1.4404 (316L)
  • Process Connection: Stainless Steel, 1.4410 (316/316L)