The Smith Meter Model K12 Meter is a 12", double-case, straight-through-type, rotary vane, positive displacement flow meter and is part of the CT series of large PD meters.

The CT series PD Meters incorporate design features including lightened blades, full-width wear strips, and tungsten carbide roller pins to provide extended service in harsh crude applications.

The crude transportation series is suitable for both crude oil and refined product applications such as blending, batching and leak detection as well as traditional custody transfer applications.
Features
  • High-viscosity meter clearances extend operation at maximum flow rate from 200 to 2,000 millipascal-second (mPa•s)
  • High-temperature clearances extend operating temperatures from 115 to 200 degrees Fahrenheit (°F) (46 to 93 degrees Celsius (°C))
  • All iron trim option for operating temperatures above 200°F (93°C)
  • Liquefied petroleum gas (LPG) trim option for low-lubricity liquids, such as LPG
  • Compliant with NACE standard MR-01-75
  • ASME Section VIII vessel construction is available for model K12-S3
The Smith Meter Model K12 Meter is a 12", double-case, straight-through-type, rotary vane, positive displacement flow meter and is part of the CT series of large PD meters.

The CT series PD Meters incorporate design features including lightened blades, full-width wear strips, and tungsten carbide roller pins to provide extended service in harsh crude applications.

The crude transportation series is suitable for both crude oil and refined product applications such as blending, batching and leak detection as well as traditional custody transfer applications.
Features
  • High-viscosity meter clearances extend operation at maximum flow rate from 200 to 2,000 millipascal-second (mPa•s)
  • High-temperature clearances extend operating temperatures from 115 to 200 degrees Fahrenheit (°F) (46 to 93 degrees Celsius (°C))
  • All iron trim option for operating temperatures above 200°F (93°C)
  • Liquefied petroleum gas (LPG) trim option for low-lubricity liquids, such as LPG
  • Compliant with NACE standard MR-01-75
  • ASME Section VIII vessel construction is available for model K12-S3
Models matching criteria: 223
Screw, Drive, #2 x ⅛" - Item 46
Contact for Availability
Screw, Calibrator Mounting - Item 50
Contact for Availability
Internal Mechanism - Fitting, Pitot - Item 81
Contact for Availability
Internal Mechanism - Pin, Lock - Item 137
Contact for Availability
Internal Mechanism - Screw, Set, ¼-20 x ¼" - Item 159
Contact for Availability
Adapter: Standard and ATC - Item 2
Contact for Availability
Housing Assembly: S1, S3, S6 Standard - Item 28
Contact for Availability
Internal Mechanism - Base - Item 70
Contact for Availability
Internal Mechanism - Cone, Shaft - Item 76
Contact for Availability
Internal Mechanism - Elbow, Pitot Fitting - Item 80
Contact for Availability
Internal Mechanism - Gear, Jackshaft Pinion: LPG - Item 87
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 1,000 SSU to 3,000 SSU - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 3,000 SSU to 5,000 SSU - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 3,000 SSU to 5,000 SSU and 200°F - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 1,000 SSU to 3,000 SSU - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 3,000 SSU to 5,000 SSU - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 5,000 SSU to 10,000 SSU - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 3,000 SSU to 5,000 SSU and 200°F - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 1,000 SSU to 3,000 SSU - Item 110
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 3,000 SSU to 5,000 SSU - Item 110
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 3,000 SSU to 5,000 SSU and 200°F - Item 110
Contact for Availability
Internal Mechanism - Pin, Dowel - Item 117
Contact for Availability
Internal Mechanism - Standard - Item 140
Contact for Availability
Internal Mechanism - Modified for 3,000 SSU to 5,000 SSU - Item 140
Contact for Availability
Internal Mechanism - Modified for 5,000 SSU to 10,000 SSU - Item 140
Contact for Availability
Internal Mechanism - Modified for 200°F - Item 140
Contact for Availability
Internal Mechanism - Modified for 1,000 SSU to 3,000 SSU and 200°F - Item 140
Contact for Availability
Internal Mechanism - Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 140
Contact for Availability
Internal Mechanism - LPG - Item 161
Contact for Availability
Internal Mechanism - LPG - Item 163
Contact for Availability
Internal Mechanism General Assembly - Barrel Geared, LPG Trim
Contact for Availability
Internal Mechanism General Assembly - Hectoliter Geared, Standard
Contact for Availability
Vent Housing - Item 11
Contact for Availability
⅜" Tubing - Item 21
Contact for Availability
Internal Mechanism - Nut, Rotor Shaft, 1¾"-8, UN-3B - Item 89
Contact for Availability
Cap, Pipe: NACE - Item 29
Contact for Availability
Internal Mechanism - Sleeve, Upper Rotor Bearing - Item 138
Contact for Availability
Internal Mechanism - Sleeve, Lower Rotor Bearing - Item 143
Contact for Availability

Specifications

Brand

Maximum Flow Rate

  • Continuous Rating with Standard Trim: 7200 BPH / 1140 m³/h
  • Continuous Rating with All Iron or LPG Trim: 5400 BPH / 855 m³/h

Repeatability

  • ± 0.02 %

Viscosity

  • Standard: 200 mPa.s³ (1,000 SSU) maximum
  • Optional: 2 Pa.s (10,000 SSU) maximum - specify "High Viscosity Meter Clearances."
  • Over 2 Pa.s: Specify "High Viscosity Meter Clearances" and derate maximum flow rate in direct proportion to viscosity over 2 Pa.s (e.g., at 4 Pa.s, derate maximum flow rate to 50 % of normal continuous rating - 3600 BPH)

Temperature - Standard Meter Clearances with

  • Buna-N/PTFE: -20° to 115° F (-29° to 46° C)
  • FKM: 10° to 115° F (-12° to 46° C)
  • Low Temperature FKM: -50° to 115° F (-46° to 46° C)

Temperature - High Temperature Meter Clearances with

  • Buna-N/PTFE: -20° to 200° F (-29° to 93° C)
  • FKM: 10° to 200° F (-12° to 93° C)
  • Low Temperature FKM: -50° to 200° F (-46° to 93° C)

Temperature - All Iron Trim with

  • Buna-N: -20° to 225° F (-29° to 108° C)
  • FKM: 10° to 400° F (-12° to 205° C)
  • Low Temperature FKM: -50° to 400° F (-46° to 205° C)

Meter Gearing

  • One barrel or 1 hectolitres per revolution of meter calibrator output shaft
  • Fifty gallons―Special