Description
Overfill protection and grounding monitor for truck or rail loading in petro-chemical applications.
Built to function with all probes designed to the API code: API RP 1004 and the EU Standard EN13922, the RM140W Series is the world’s most flexible and adaptable monitor.
The RM140W provides a fail-safe, state-of-the-art overfill protection and grounding monitoring system that is compatible with all commonly used overfill protection and grounding systems.
Features
- Automatic Sensing of 2-Wire/Thermistor or 5-Wire Overfill Systems, No Manual Switching or Inspection Required
- Supports Up to 8 2-Wire/Thermistor Probes and Up to 12 5-Wire Probes
- High-output Display Visible in Direct Sunlight, Provides Flexibility for Indoor/Outdoor Use
- Coded Wireless By-pass Key for Secure and Reliable Operation
- Self-test at Start Up/Continuous Self-monitoring, Ensures Safety Throughout the Loading Process
- Separate Grounding and Overfill Control Outputs
- Compact and Functional Design is Easy to Install, Perfect for Tight Spaces or Crowded Work Areas
- Global Electronic Compatibility, Able to Operate on Almost Any Electric Service
- RM100 is Directly Compatible with PD100 Probe Doctor as a “Plug-in Replacement”
Inventory
Displaying prices & availability for Ohio, United States 43201 in USD. Change location.
Models matching criteria: 11
Fuse 400mA, 250VAC Anti-surge, 1500A Breaking Capacity
Contact for Availability
Fuse 5A at 250VAC Anti-surge
Contact for Availability
RM100 Safety Ground Harness
Contact for Availability
RM100 Aluminium Safety Barrier
Contact for Availability
RM100 Polycarbonate Terminal Cover
Contact for Availability
RM100 PCB Assembly Complete Kit: RM100-5 + 6959 Display
Contact for Availability
Civacon Junction Box
Contact for Availability
Civacon 6-Channel Thermistor Plug
Contact for Availability
Civacon Optic Plug
Contact for Availability
Civacon Earth Clamp with Straight Cable
Contact for Availability
RM140W Bypass Fob
Contact for Availability
Specifications
Specifications
Brand
Power
- 240 V Operation
- 110 V Operation
Minimum Input Voltage
- 185 Vac
- 85 Vac
Maximum Input Voltage
- 275 Vac
- 135 Vac
In-rush Current
- 2.2A
- 2.3A
Maximum Current
- 400 mA
Normal Power Consumption
- 8.6W - No probe
- 20W - 8x 2-wire probes
Mains Power Fuse Rating
- 250 V, 400 mA anti-surge 1500 A Breaking Capacity
Nominal Voltage
- 10.5 V
- 13.02 V Max.
Nominal Current
- 116 mA
- 121 mA Max.
Relay Outputs
- Overfill Monitoring Relay
Relay Contacts
- Common
- Normally Open
- Normally Closed
Maximum Contact Voltage
- 250 Vac
Maximum Contact Load
- 5A - resistive
- 2.5A - inductive
Relay Fuse Rating
- 250 V at 5A anti-surge
Width
- 12.8"
- 324 mm
Height
- 13.4"
- 340 mm
Depth
- 13.4"
- 170 mm
Weight
- 36.37 lb
- 16.5 kg
Material
- Aluminium Housing Base and Cover
- Laminated Glass Window
Type of Protection
- Explosion-proof enclosure for Group II, Zone 1, Ex d [ia]
IEC Certificate Marking
- IECEx TSA 05.0049X Ex d [ia] IIB T6 (Tamb=60° C) IP66
ATEX Certificate Marking
- DEMKO 06 ATEX 140833X 0518 II 2 (1) G EEx d [ia] IIB T6 Ta = -20° to 60° C
EU Directives
- 73/23/EEC & 93/68/EEC (Low Voltage) 94/9/EC (ATEX) 89/336/EEC (EMC) 2002/95/EC (RoHS) Compatible with EN 13922
FM Approval Marking
- FM Approved for US and Canada. Explosionproof with I.S. Outputs Intrinsically Safe Sécurité Intrinsèque Exia Class I, Div. 1, Group C & D, T6 Ta = -25° to 60° C