Description
The Smith Meter Model K12 Meter is a 12", double-case, straight-through-type, rotary vane, positive displacement flow meter and is part of the CT series of large PD meters.
The CT series PD Meters incorporate design features including lightened blades, full-width wear strips, and tungsten carbide roller pins to provide extended service in harsh crude applications.
The crude transportation series is suitable for both crude oil and refined product applications such as blending, batching and leak detection as well as traditional custody transfer applications.
Features- High-viscosity meter clearances extend operation at maximum flow rate from 200 to 2,000 millipascal-second (mPa•s)
- High-temperature clearances extend operating temperatures from 115 to 200 degrees Fahrenheit (°F) (46 to 93 degrees Celsius (°C))
- All iron trim option for operating temperatures above 200°F (93°C)
- Liquefied petroleum gas (LPG) trim option for low-lubricity liquids, such as LPG
- Compliant with NACE standard MR-01-75
- ASME Section VIII vessel construction is available for model K12-S3
Inventory
Displaying prices & availability for Ohio, United States 43201 in USD. Change location.
Models matching criteria: 201
Screw, Drive, #2 x ⅛" - Item 46
Contact for Availability
Screw, Calibrator Mounting - Item 50
Contact for Availability
Screw, Cover Plate, #10-32 x ⅜" - Item 51
Contact for Availability
Internal Mechanism - Fitting, Pitot - Item 81
Contact for Availability
Internal Mechanism - Screw, Set, ¼-20 x ¼" - Item 159
Contact for Availability
Internal Mechanism - Pin, Lock - Item 137
Contact for Availability
Internal Mechanism - Pin, Cotter, 3/32 x 1" - Item 116
Contact for Availability
Stem, Adjusting - Item 65
Contact for Availability
Adapter: Standard and ATC - Item 2
Contact for Availability
Internal Mechanism - Block: Standard - Item 71
Contact for Availability
Internal Mechanism - Block: High Viscosity for 1,000 SSU to 3,000 SSU - Item 71
Contact for Availability
Internal Mechanism - Block: High Viscosity for 3,000 SSU to 5,000 SSU - Item 71
Contact for Availability
Internal Mechanism - Gear, Idler: Barrels, LPG - Item 85
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 5,000 SSU to 10,000 SSU - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Upper: Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 98
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 1,000 SSU to 3,000 SSU - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 5,000 SSU to 10,000 SSU - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 3,000 SSU to 5,000 SSU and 200°F - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Lower: Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 99
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 1,000 SSU to 3,000 SSU - Item 110
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 3,000 SSU to 5,000 SSU - Item 110
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 5,000 SSU to 10,000 SSU - Item 110
Contact for Availability
Internal Mechanism - Blade Assembly, Middle: Modified for 1,000 SSU to 3,000 SSU and 200°F - Item 110
Contact for Availability
Internal Mechanism - Pin, Dowel - Item 117
Contact for Availability
Internal Mechanism - Shaft - Item 127
Contact for Availability
Internal Mechanism - Collar - Item 128
Contact for Availability
Internal Mechanism - Plate, Rotor Gear - Item 135
Contact for Availability
Internal Mechanism - Modified for 3,000 SSU to 5,000 SSU - Item 140
Contact for Availability
Internal Mechanism - Modified for 200°F - Item 140
Contact for Availability
Internal Mechanism - Modified for 3,000 SSU to 5,000 SSU and 200°F - Item 140
Contact for Availability
Internal Mechanism - Modified for 5,000 SSU to 10,000 SSU and 200°F - Item 140
Contact for Availability
Internal Mechanism - LPG - Item 161
Contact for Availability
Internal Mechanism - LPG - Item 162
Contact for Availability
Internal Mechanism - LPG - Item 163
Contact for Availability
Internal Mechanism General Assembly - Barrel Geared, Standard
Contact for Availability
Internal Mechanism General Assembly - Barrel Geared, All Iron Trim
Contact for Availability
Internal Mechanism General Assembly - Hectoliter Geared, LPG Trim
Contact for Availability
Internal Mechanism - Screw, Rotor Shaft, ¾-10 x 2¼" - Item 158
Contact for Availability
Internal Mechanism - Sleeve, Lower Rotor Bearing - Item 143 view more
Not sold as a separate component - included with item 140
Contact for Availability
Internal Mechanism - Sleeve, Upper Rotor Bearing - Item 138
Contact for Availability
Specifications
Specifications
Brand
Maximum Flow Rate
- Continuous Rating with Standard Trim: 7200 BPH / 1140 m³/h
- Continuous Rating with All Iron or LPG Trim: 5400 BPH / 855 m³/h
Repeatability
- ± 0.02 %
Viscosity
- Standard: 200 mPa.s³ (1,000 SSU) maximum
- Optional: 2 Pa.s (10,000 SSU) maximum - specify "High Viscosity Meter Clearances."
- Over 2 Pa.s: Specify "High Viscosity Meter Clearances" and derate maximum flow rate in direct proportion to viscosity over 2 Pa.s (e.g., at 4 Pa.s, derate maximum flow rate to 50 % of normal continuous rating - 3600 BPH)
Temperature - Standard Meter Clearances with
- Buna-N/PTFE: -20° to 115° F (-29° to 46° C)
- FKM: 10° to 115° F (-12° to 46° C)
- Low Temperature FKM: -50° to 115° F (-46° to 46° C)
Temperature - High Temperature Meter Clearances with
- Buna-N/PTFE: -20° to 200° F (-29° to 93° C)
- FKM: 10° to 200° F (-12° to 93° C)
- Low Temperature FKM: -50° to 200° F (-46° to 93° C)
Temperature - All Iron Trim with
- Buna-N: -20° to 225° F (-29° to 108° C)
- FKM: 10° to 400° F (-12° to 205° C)
- Low Temperature FKM: -50° to 400° F (-46° to 205° C)
Meter Gearing
- One barrel or 1 hectolitres per revolution of meter calibrator output shaft
- Fifty gallons―Special