UFM 800 W/C & UFM 800 W Hot Tapping Ultrasonic Flowmeter

Brand: Krohne
UFM 800 W
Ultrasonic flowmeters with UFS 800 W sensors for measuring the volumetric flowrate in metal pipelines. The sensors are welded to the outside of the pipelines.

UFM 800 C
Ultrasonic flowmeter with UFS 800 C sensors for measuring flow velocity in open channels. The sensors can be installed or mounted from the inside or outside of the channel.

Advantages
  • No constriction of the pipe cross-section
  • No additional pressure drop
  • Electrical conductivity, pressure, density, etc. have no effect on measurements
  • Easy to install from outside or inside
  • No maintenance requirement
  • Low power consumption
  • Low operating costs
show more
UFM 800 W
Ultrasonic flowmeters with UFS 800 W sensors for measuring the volumetric flowrate in metal pipelines. The sensors are welded to the outside of the pipelines.

UFM 800 C
Ultrasonic flowmeter with UFS 800 C sensors for measuring flow velocity in open channels. The sensors can be installed or mounted from the inside or outside of the channel.

Advantages
  • No constriction of the pipe cross-section
  • No additional pressure drop
  • Electrical conductivity, pressure, density, etc. have no effect on measurements
  • Easy to install from outside or inside
  • No maintenance requirement
  • Low power consumption
  • Low operating costs

Specifications

Brand

Accuracy

  • Error: Double Beam < ± 0.7 % of Measured Value - UFM 800 W
  • Error: Single Beam < ± 1 % of Measured Value - UFM 800 W
  • Error: Single Beam ± 5 % of Measured Value - UFM 800 C
  • Error: Triple Beam < ± 0.5 % of Measured Value - UFM 800 W

Ambient Temperature Range

  • -25° to 60° C (-13° to 140° F)

Applications

  • Actual Volume Flowrate
  • Transit Time Measurement - UFM 800 W

Approvals & Certifications

  • ATEX
  • CE
  • TÜV

Cable Length

  • Signal Cable: 15 feet (5 metres) - Standard

Communication

  • HART
  • PROFIBUS PA

Consumption

  • Power: 10 VA - for AC
  • Power: 10 W - for DC

Diameter

  • Signal Cable: 0.43” (11 mm)

Display

  • 3-field LCD Display
  • Backlit

Duty Cycle

  • 25 to 500 milliseconds for Frequency < 10 Hz

Electrical Connectors

  • Coaxial Cable

Environmental Protection

  • IP65
  • IP66
  • IP67
  • IP68
  • NEMA 4
  • NEMA 4C - UFM 800 C
  • NEMA 4X - UFM 800 W
  • NEMA 6

Flow Rate

  • Flow Velocity: 1.5 to 60 FPS (0.5 to 20 mps)

Isolation

  • All Inputs & Outputs are Galvanically Isolated

Load

  • ≤ 600 ohms at Current Output

Materials of Construction

  • Sensor Mount: 304 Stainless Steel, 1.4301
  • Sensor Mount: Viton - UFM 800 C

Media

  • Liquids

Output

  • Frequency: 0 to 2,000 Hz

Output Format

  • Current Output
  • Pulse Output

Power Supply

  • 100-240 Vac (10 %, -15 %), 48 to 63 Hz
  • Low Voltage: 18-35 Vdc
  • Low Voltage: 24 Vac (-10 %, 15 %), 48 to 63 Hz
  • Low Voltage: 24 Vdc

Pressure Range

  • bar: 0 to 10 - UFM 800 C
  • bar: 0 to 40 - UFM 800 W
  • kPa: 0 to 1,000 - UFM 800 C
  • kPa: 0 to 4,000 - UFM 800 W
  • psig: 0 to 150 - UFM 800 C
  • psig: 0 to 580 - UFM 800 W

Pressure Type

  • Gauge

Process Temperature

  • -25° to 120° C (-13° to 248° F) - UFM 800 C
  • -50° to 180° C (-58° to 356° F) - UFM 800 W

Repeatability

  • ± 0.2 % of Measured Value

Sensor, Probe Material

  • 304 Stainless Steel, 1.4301 - UFM 800 C
  • 316L Stainless Steel, 1.4401 - UFM 800 W
  • Pyrex - UFM 800 C
  • Viton - UFM 800 C

Sensor, Probe Style

  • Ultrasonic

Storage Temperature

  • -40° to 65° C (-40° to 149° F)

Time Constant

  • 0.025 to 99 seconds