Images are representations only.

BE/HR-E Deflagration Flame Arrester

Brand: PROTEGO
The Protego BE/HR-E end-of-line deflagration flame arrester was specifically developed for vessels which are not pressurized and store Ethanol or other alcohols with a MESG ≥ 0,85 mm.

The combustion of alcohol requires a modified flame arrester element design to provide protection against endurance burning.

In addition, the device provides protection against atmospheric deflagration.

Main application area is on suction and vent lines, with the goal to prevent flame transmission caused by endurance burning or atmospheric deflagration from propagating into the vessel or plant.
Features
  • Endurance burning protection for alcohols and hydrocarbons with a MESG ≥ 0.85 mm
  • Weather hood protects against environmental impact (i.e. Weather, bird nests, etc.)
  • Weather hood opens and signals the impact of a flame
  • Fusible link is resistant against chemicals
  • Modular design allows replacement of single FLAMEFILTER
  • Protection against atmospheric deflagration and endurance burning
show more
The Protego BE/HR-E end-of-line deflagration flame arrester was specifically developed for vessels which are not pressurized and store Ethanol or other alcohols with a MESG ≥ 0,85 mm.

The combustion of alcohol requires a modified flame arrester element design to provide protection against endurance burning.

In addition, the device provides protection against atmospheric deflagration.

Main application area is on suction and vent lines, with the goal to prevent flame transmission caused by endurance burning or atmospheric deflagration from propagating into the vessel or plant.
Features
  • Endurance burning protection for alcohols and hydrocarbons with a MESG ≥ 0.85 mm
  • Weather hood protects against environmental impact (i.e. Weather, bird nests, etc.)
  • Weather hood opens and signals the impact of a flame
  • Fusible link is resistant against chemicals
  • Modular design allows replacement of single FLAMEFILTER
  • Protection against atmospheric deflagration and endurance burning
2 models matching criteria
  • Model - End-Of-Line Deflagration Flame Arrester
Out of Stock
  • Model - End-Of-Line Deflagration Flame Arrester with Heating Jacket
Out of Stock

Specifications

Brand

Approvals & Certifications

  • EN ISO 16852, 6358
  • TÜV (Technischer Uberwachungsverein)

Approvals & Certifications

  • ATEX
  • CEN
  • IEC
  • NEC

Enclosure, Body Material

  • Weather Hood: Stainless Steel
  • Weather Hood: Steel

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# ASME B16.5

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# ASME B16.5

Flange Type

  • Raised Face (RF)
  • Smooth Finish

Materials of Construction

  • Flamefilter, Spacer: Hastelloy
  • Flamefilter, Spacer: Stainless Steel

Operating Temperature

  • 0° to 60° C (32° to 140° F)