Description
The Model 8460 has been engineered to automatically recognize the type of overfill system - either optic or thermistor-signal - that is being used on a transport.
When connected to the transport, the status of sensors within the tanks or compartments is monitored with automatic warning of product-overfill detection occurring at predetermined levels.
Features- Automatic Switching Operation Eliminates Need For Manual Setting
 - Combined Optic and Thermistor Technology Removes Uncertainty Regarding which is Being
 - Used on the Transport
 - Compatible with all 5-wire Optic, Thermistor and Thermo-Optic Sensors
 - 0.5-second Maximum Response Time
 - Will Load All Trailers with Any Brand/Style of Overfill-detection System
 - Ground Verification Included via Separate Relay Contact
 - Overfill Detection and Ground Verification Signaled Separately to Terminal Automation System: TAS
 - Maximum Flexibility at the Loading Terminal without Compromising Safety
 - LED Lamps for Long Life and Reliability
 
Specifications
Specifications
Brand
Operating Temperature
- -40° to 158° F
 - -40° to 70° C
 
Input Requirements
- 120 Vac 60 Hz
 - 15 VA - Standard
 - 120 Vac Available - Please Inquire
 
Output Relay Contacts
- 240 Vac
 - 5A DPDT
 
Response Time
- 0.5 Seconds Max.
 - Dry to Wet Transition
 
Electrical Connections
- Internal Terminal Strips
 
Enclosures
- NEMA 4 Explosion-proof
 
Housing Material
- Aluminum
 
Approximate Weight
- 8400 - 30 lb
 - 8420 - 31 lb
 - 8440 - 32 lb
 - 8460 - 32 lb
 
Approvals
- Factory Mutual
 - CSA
 
Installation Information
- Provided with the monitor.
 - Can also be accessed and downloaded via website.