Images are representations only.

RS-1/RS-2 Recovery / Reinjection System

Brand: Meter Engineers
The RS-1/2 can be incorporated into any sampling or slipstream process unit. It is designed to reinject the product used by the unit, eliminating unwanted product in the station sump system.

The RS-1/2 Recovery/Re-Injection System consists of a 15-gallon stainless steel tank, 4 level stainless steel float system, 2 HP or 3 HP explosion proof motor, reduction gear box, positive displacement pump, and a programmable logic controller (PLC). The RS-1/2 Recovery/Re-Injection System has 3 modes of operation.
Features
  • NORMAL CYCLE:  With the selector switch in the NORMAL position, the product enters the recovery tank from the flasher as it is running. The product will rise in the tank until it reaches the 9.4-gallon level float switch (LS1, high level). The motor/pump will start injecting products into the pipeline until the product level decreases below the lowest level float switch. If the Process Unit should stop, then the RS-1/2 can be interconnected to stop also. When the unit resumes operation, the RS-1/2 will start injecting again once the product level has risen above the LS2 float level switch. The tank will be pumped empty in approximately 5 minutes
  • FAST CYCLE: In the fast cycle mode, (selector switch in the FAST position) the pump will start when the product level reaches the 3.7-gallon lowest level float switch. The tank will be pumped empty in approximately 2 minutes
  • MANUAL CYCLE: In the manual cycle mode, (selector switch in the MANUAL position) the pump unit will run if the product level is above the lowest level float switch
  • ALARM CONDITIONS: The RS-1/2 Recovery System has alarm outputs to alert station personnel of an abnormal or malfunction condition and PLC protection to prevent tank overflow or pump/motor damage
show more
The RS-1/2 can be incorporated into any sampling or slipstream process unit. It is designed to reinject the product used by the unit, eliminating unwanted product in the station sump system.

The RS-1/2 Recovery/Re-Injection System consists of a 15-gallon stainless steel tank, 4 level stainless steel float system, 2 HP or 3 HP explosion proof motor, reduction gear box, positive displacement pump, and a programmable logic controller (PLC). The RS-1/2 Recovery/Re-Injection System has 3 modes of operation.
Features
  • NORMAL CYCLE:  With the selector switch in the NORMAL position, the product enters the recovery tank from the flasher as it is running. The product will rise in the tank until it reaches the 9.4-gallon level float switch (LS1, high level). The motor/pump will start injecting products into the pipeline until the product level decreases below the lowest level float switch. If the Process Unit should stop, then the RS-1/2 can be interconnected to stop also. When the unit resumes operation, the RS-1/2 will start injecting again once the product level has risen above the LS2 float level switch. The tank will be pumped empty in approximately 5 minutes
  • FAST CYCLE: In the fast cycle mode, (selector switch in the FAST position) the pump will start when the product level reaches the 3.7-gallon lowest level float switch. The tank will be pumped empty in approximately 2 minutes
  • MANUAL CYCLE: In the manual cycle mode, (selector switch in the MANUAL position) the pump unit will run if the product level is above the lowest level float switch
  • ALARM CONDITIONS: The RS-1/2 Recovery System has alarm outputs to alert station personnel of an abnormal or malfunction condition and PLC protection to prevent tank overflow or pump/motor damage
2 models matching criteria
15-gallon stainless steel tank, 4 level stainless steel float system, 2 HP explosion proof motor
In Stock
15-gallon stainless steel tank, 4 level stainless steel float system, 3 HP explosion proof motor,
In Stock

Specifications

Pump Discharge Connection

  • 1/2 Swagelok Stainless Steel Tubing/Hose

Pump Inlet Filtration

  • 230 Micron T Type Filter

Discharge Valve Cracking Pressure

  • 100 psig

Discharge Valve Pressure

  • 1,225 psig
  • 2,225 psig

Frame

  • 184 C Face
  • 215 C Face

Motor HP

  • 2
  • 3

Motor RPM

  • 1,725

Helical Gear Ratio

  • 2.7:1
  • 4.13:1

Recovery Tank Capacity

  • 15 Gal

Materials of Construction

  • 12 Gauge: 304 Stainless Steel

Pump GPM

  • 1.85
  • 4

Pump Output Pressure

  • Maximum 1,200 psig
  • Maximum 2,200 psig

Input Voltage

  • 230 Vac Single Phase (With Neutral for 115 Vac Control)
  • 208-230 Vac Single Phase (With Neutral for 115 Vac Control)

Input Current

  • 11.6 A
  • 15 A

Customer Status Input

  • Remote Pump Run Command

Customer Status Output

  • High-High Tank Level (2 Form C, 10 Amp Dry Contacts)
  • Alarm/Malfunction (2 Form C 10 Amp Dry Contacts)
  • Pump On (PLC 2 Amp Contact, Common to Outputs 0-3)
  • High Tank Level (PLC 2 Amp Contact, Common to Outputs 0-3)