The Smith Meter AccuLoad® IV family of electronic preset delivery systems provides safe, reliable control and accurate measurement for custody transfer loading and unloading of petroleum liquid products.
With several models to choose from, you can find one that is right for any application, whether it is part of a complex system involving automation, blending, and numerous load arms, or a small-scale bulk plant.
The AccuLoad® product line has been continuously refined for over 35 years to provide the ultimate in features and flexibility.
The AccuLoad® IV is tailored for current operations and adaptable to future growth and enhancements.
Features
Individually configurable loading arm functions for:
Straight product delivery
Sequential blending
Ratio blending
Hybrid blending
Vapor recovery unit (VRU) operation
Unloading operation
Up to six products for each load arm
Simultaneous operation of all load arms
User-configurable inputs and outputs
Additive control for metered, smart, and piston injectors
Digital or analog valve flow control
Single- and dual-channel meter pulse inputs
Fully configurable flow profile
Alarm monitoring with configurable action
Standalone operation or remote-controlled through-communication link
Measurement profile:
Automatic temperature and pressure compensation and density correction
American Petroleum Institute (API) tables for light products to crude oils
Biofuel volumetric compensation
Meter factor linearization
Extensive security:
Five levels of passcodes
Per-parameter access control
Audit log of parameter changes
Onboard diagnostics:
Detailed operational status
Manual control of inputs/outputs
Event logging
Communication monitoring
Valve solenoid maintenance monitoring
Valve tuning assistance
Ethernet and serial communications:
Modbus
Network printing
Proximity card reader
Driver access database
Promass interface
Configurable bill of lading (BOL)
Browser-based remote access:
Control/monitoring of loading process
Diagnostic information
Virtual loading screen anywhere on the network
Built-in virtual load rack (VLR) simulates loading rack equipment for diagnostics and training
Boolean/algebraic processing
Automatic flow control with recovery
Linux operating system for networking
Color liquid-crystal display (LCD) with touch screen user interface
The Smith Meter AccuLoad® IV family of electronic preset delivery systems provides safe, reliable control and accurate measurement for custody transfer loading and unloading of petroleum liquid products.
With several models to choose from, you can find one that is right for any application, whether it is part of a complex system involving automation, blending, and numerous load arms, or a small-scale bulk plant.
The AccuLoad® product line has been continuously refined for over 35 years to provide the ultimate in features and flexibility.
The AccuLoad® IV is tailored for current operations and adaptable to future growth and enhancements.
Features
Individually configurable loading arm functions for:
Straight product delivery
Sequential blending
Ratio blending
Hybrid blending
Vapor recovery unit (VRU) operation
Unloading operation
Up to six products for each load arm
Simultaneous operation of all load arms
User-configurable inputs and outputs
Additive control for metered, smart, and piston injectors
Digital or analog valve flow control
Single- and dual-channel meter pulse inputs
Fully configurable flow profile
Alarm monitoring with configurable action
Standalone operation or remote-controlled through-communication link
Measurement profile:
Automatic temperature and pressure compensation and density correction
American Petroleum Institute (API) tables for light products to crude oils
Biofuel volumetric compensation
Meter factor linearization
Extensive security:
Five levels of passcodes
Per-parameter access control
Audit log of parameter changes
Onboard diagnostics:
Detailed operational status
Manual control of inputs/outputs
Event logging
Communication monitoring
Valve solenoid maintenance monitoring
Valve tuning assistance
Ethernet and serial communications:
Modbus
Network printing
Proximity card reader
Driver access database
Promass interface
Configurable bill of lading (BOL)
Browser-based remote access:
Control/monitoring of loading process
Diagnostic information
Virtual loading screen anywhere on the network
Built-in virtual load rack (VLR) simulates loading rack equipment for diagnostics and training
Boolean/algebraic processing
Automatic flow control with recovery
Linux operating system for networking
Color liquid-crystal display (LCD) with touch screen user interface
Calculated Accuracy: The gross at standard temperature to gross volume ratio, excluding the accuracy of fluid temperature measurement, exactly matches the proper volume correction factor of ASTM-D-1250-04 over the fluid temperature range of -58° to 302° F (-50° to 150° C)
Temperature Measurement Accuracy: Fluid temperature is measured to within ± 0.72° F (± 0.4° C) over the fluid temperature range of -328° to 572° F (-200° to 300° C). Fluid temperature is measured to within ± 0.45° F (± 0.25° C) over the fluid temperature range of 32° to 572° F (0° to 300° C).
Stability: 0.1° F (0.06° C)/year
Flow Totalizing: Within one pulse of input frequency
Electromagnetic Compatibility (EMC)
EMC Directive 2014/30/EU
EN 61326-1: Electrical equipment for measurement, control and laboratory use
Environment
Ambient Operating Temperature: -40° to 140° F (-40° to 60° C)