Description
The ASCO Series RCS redundant control system is a pilot valve system with no single point of failure that can result in unwanted closure of the process valve. It is suitable for use in SIL 3 applications and greatly reduces spurious trip rates.
The ASCO Series RCS achieves a higher level of process safety and reliability by using a redundant, fault-tolerant architecture, high diagnostic coverage, and automated testing.
It is available in a variety of constructions that provide valve diagnostics through automated, partial-stroke testing.
The availability and reliability of The ASCO Series RCS provides the customer´s best choice for process valve diagnostics and actuation.
Features- Keyed bypass allows on-line maintenance without process interruption
- High safety availability
- No nuisance trips
- Optional stainless-steel construction
Specifications
Specifications
Brand
Valve Actuation
- Solenoid - Air Pilot
Body Material
- Aluminum, Engineered Plastics, Stainless Steel
Media
- Air, Inert Gas
Port Type
- Female NPT
Function
- Redundant valves in 2oo2 or 2oo3 configuration (Normally Closed or Normally Open)
Flow
- From 2.0 Cv to 3.0 Cv
Voltage
- 110 AC, 120 AC, 230 AC, 12 DC, 24 DC, 48 DC, 120 DC
Maximum Differential, Maximum Operating Pressure
- Vacuum to 150 psig
Operating Environment
- Corrosive, Hazardous, Indoor, Outdoor
Standards & Regulations
- IEC 60529 (Ingress Protection), ATEX, ISO, IP65
Documentation
Documentation
Product Manuals
- Maintenance Guide: I&M RCS 2oo2D Sheet pdf 1.6 MB
- Maintenance Guide: I&M RCS 2oo3B Sheet pdf 1.7 MB
- Maintenance Guide: I&M RCS 2oo3D Sheet pdf 2.4 MB
- Maintenance Guide: I&M RCS Sheet pdf 1.7 MB
- Maintenance Guide: Series RCS 316L Redundant Control Systems pdf 1.3 MB
- RCS Safety Manual: Redundant Control System pdf 1.4 MB