Images are representations only.

3051CFC Compact Conditioning Orifice Plate Flow Meter

Brand: Rosemount
Providing precise flow measurements, the Rosemount 3051CFC Compact Conditioning Orifice Plate Flow Meter is an industry-leading solution designed with a compact conditioning orifice plate.

This conditioning plate has a patented 4-hole design which enables accurate measurement downstream of flow disturbances.

This conditioning orifice plate also reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream for installation in tight areas.
Features
  • Patented 4-hole orifice plate design enables accurate flow measurement near upstream flow disturbances.
  • Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
  • 10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
  • Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
  • Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
  • Loop Integrity diagnostics detect electrical loop issues for reduced downtime
  • SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
show more
Providing precise flow measurements, the Rosemount 3051CFC Compact Conditioning Orifice Plate Flow Meter is an industry-leading solution designed with a compact conditioning orifice plate.

This conditioning plate has a patented 4-hole design which enables accurate measurement downstream of flow disturbances.

This conditioning orifice plate also reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream for installation in tight areas.
Features
  • Patented 4-hole orifice plate design enables accurate flow measurement near upstream flow disturbances.
  • Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
  • 10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
  • Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
  • Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
  • Loop Integrity diagnostics detect electrical loop issues for reduced downtime
  • SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

Specifications

Brand

Accuracy

  • ± 1.75 % to ± 2.10 % of Flow Rate at 8: 1 Flow Turndown

Alarm

  • Custom Alarm & Saturation Signal Levels
  • NAMUR Alarm & Saturation Signal Levels

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Applications

  • Marine & Offshore Applications

Approvals & Certifications

  • ATEX
  • CSA
  • FM
  • IEC Ex
  • INMETRO
  • NEPSI

Configuration

  • 4-20 mA HART
  • FOUNDATION Fieldbus Protocols
  • Low-Power, 1-5 Vdc with Digital Signal based on HART Protocol
  • PROFIBUS PA Protocol
  • Wireless Protocols

Damping Adjustment

  • User Configurable from 0 to 60 seconds

Display

  • LCD Display
  • LCD Display with Local Operator Interface
  • None

Drain, Vent Valves & Plug

  • 316 Stainless Steel
  • Hastelloy C-276
  • Monel 400

Electrical Connectors

  • 1/2” NPT
  • G 1/2”
  • M20 x 1.5

Electromagnetic Interference Effect

  • Meets All Relevant Requirements of EN 61326 & NAMUR NE-21

Enclosure Finish

  • Polyurethane Paint

Enclosure, Body Material

  • Cast Stainless Steel
  • Low-Copper Aluminum

Environmental Protection

  • IP66
  • IP67
  • IP68
  • NEMA 4X / IP66, 67, 68

Fill Material

  • Inert Sensor Fill
  • Silicone Oil

Flange Material

  • 316 Stainless Steel
  • Alloy 400 or Monel
  • Hastelloy C-276
  • Plated Carbon Steel

Humidity

  • 0 to 100 % Relative Humidity

Input Power

  • 1-5 Vdc HART Low Power: 9-28 Vdc
  • 4-20 mA HART: 10.5-42.4 Vdc
  • FOUNDATION Fieldbus: 9-32 Vdc
  • PROFIBUS: 9-32 Vdc

NACE & NIST

  • NACE MR-0175, ISO 15156

O-Ring Material

  • Buna-N
  • Glass-Filled PTFE
  • Graphite-Filled PTFE

Output

  • 2.4 GHz DSSS
  • 2-Wire 4-20 mA
  • 3-Wire 1-5 Vdc

Overpressure & Static Pressure Limits

  • psig: 750 to 4,500 (bar: 51.7 to 310.3, kPa: 5,171 to 31,026)

Power Supply Effect

  • ± 0.005 % of Calibrated Span Per Volt

Pressure Range

  • bar: 0 to 2.4
  • Inches WC: 0 to 1,000 (mbar: 0 to 2488)
  • kPa: 0 to 249
  • psi: 0 to 36.12

Pressure Type

  • Differential

Process Temperature

  • -40° to 149° C (-40° to 300° F)

Stability

  • ± 0.2 % of URL for 10-Years

Storage Temperature

  • -46° to 110° C (-50° to 230° F)

Vibration Effect

  • > ± 0.1 % of URL

Volumetric Displacement

  • > 0.005”³ (0.08 cm³)

Wetted Materials

  • 316 Stainless Steel
  • Alloy 400 or Monel
  • Hastelloy C-276
  • Plated Carbon Steel

Documentation