Alarm
- Custom Alarm & Saturation Signal Levels
- NAMUR Alarm & Saturation Signal Levels
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Applications
- Marine & Offshore Applications
Approvals & Certifications
- ATEX
- CSA
- FM
- IEC Ex
- INMETRO
- TIIS
BSP Connection
- G 1/2" Male DIN 16288
- 1/4" BSPT Female
Burst Pressure
- bar: 758.4
- kPa: 75,842
- psig: 11,000
Damping Adjustment
- User Configurable from 0 to 60 seconds
Diaphragm Material
- 316L Stainless Steel
- Hastelloy C-276
Electrical Connectors
- 1/2" NPT
- G 1/2" Female
- M20 3 1.5
Environmental Protection
- IP65
- IP67
- NEMA 4X / IP65, 67
Fill Material
- Inert Oil Fill
- Silicone Oil
Input Power
- Vdc: 10.5-42.5 with No Load (5.8-28 V for Low Power)
Mounting
- 316 Stainless Steel Bracket & Accessories
Overpressure & Static Pressure Limits
- Range 1: 120 psig Max.
- Range 2 to 4: 2 x URL
Power Supply Effect
- ± 0.005 % of Calibrated Span Per Volt
Pressure Range
- bar: -1.0 to 276
- kPa: -101.4 to 27,579
- psig: -14.7 to 4,000
Process Temperature
- -40° to 121° C (-40° to 250° F)
PT/PF/PS (JIS) Connection
Storage Temperature
- -46° to 110° C (-50° to 230° F)
Temperature Effect
- ± (0.15 % of URL + 0.15 % of Span)
Volumetric Displacement
- Less than 0.0005 in³ (0.008 cm³)
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276